Products
Tsuruga Electric - AC W High Speed Tester, 8508

Tsuruga Electric - AC W High Speed Tester, 8508

Brand: Tsuruga Electric
Model No: 8508
$0.00
Qty: Add to Cart

AC-W High Speed Tester 8508 is fast response withstand voltage tester which judges by 2 cycles of applied voltage and minimum 50ms of tact time is realized. This tester can be used for mass-production of multipin connectors and multi-core harnesses which requires numerous tests. This is new model which has a variety of characteristics like peak-hold judgement of leakage current, 8 patterns of test condition memories and interface RS-232C as the standard product.

 

Characteristics

  • High speed withstand voltage test (50ms)
  • Leakage current is measured by Peak-hold method
  • High visibility OLED display
  • Available with 8 patterns of test condition memories
  • Interface RS-232C is included in standard product
  • Available with correction function for fluctuations of test voltage depending on loads

Typical application in multipin connector, multi-core harness etc.

 

Basic Specifications

Test Voltage
Applied voltageAC 0.05 to 6.00 kV (Frequency 50/60 Hz Switchable)
Output capacity6 VA (0.6 kV, 10 mA)
Maximum current output: within 60s during continuous test
WaveformSine wave (Rate of distortion: Less than 5%, No-load)
Voltage regulationLess than 10% (No-load→Maximum load)
Voltage application methodZero-cross Start / End
Voltage settingDigital setting (resolution: 0.01kV)
Voltage Measurement
Rectification methodAverage rectified effective value display
Measurement range0 to 600V (resolution: 1V)
Measurement accuracy+/- (1.5% of rdg. +20V)
Current Measurement
Rectification methodPeak value display
Measurement range0.00 to 15.00mA (resolution: 0.01mA)
Measurement accuracy+/- (2% of rdg. +0.05mA)
Judgement of Test Result
Judgement methodUpper limit: Comparison of peak values with analog and digital comparator
Lower limit: Digital comparator (Comparison when time is up)
Setting rangeUpper limit: 0.01 to 15.00 mA
Lower limit: 0.01 to 15.00 mA / OFF
Judgment conditionsUpper limit setting>Leakage current>Lower limit setting・・・GOOD
Upper limit setting≦Leakage current・・・・・・・・HIGH NG
Lower limit setting≧Leakage current・・・・・・・・LOW NG
Test time
Setting range2 cycles to 60s (resolution: 1cycle)

 

Power supplyAC100 to 240V, 50/60Hz  (Allowable voltage range: AC90 to  250V)
Power consumptionApprox. 17 VA (during no load)
Approx. 65 VA (during max. rated load)
Operating environment0 to 40℃, 20 to 80%RH (No condensation)
Withstand voltagePower supply terminal - External case: AC 1350 V, 1 min.
Dimension260(W) x 246(D) x 110(H) mm  (excluding buttons and legs)
WeightApprox. 4.5 kg
AccessoriesHigh voltage cable 2m ・・・1piece
Low voltage cable 2m ・・・1piece
Earth wire 3m ・・・1piece
Power code 2.5m ・・・1piece
REMOTE I/O plug ・・・1piece
Operating manual ・・・1part