With bus inteface
The AP05 position indicator guides the user intuitively to the correct machine setting in the case of product or format change. The optimized backlit display indicates target values and actual values straight to the point. Two LEDs show the machine operator precisely the direction whereto the adjustment is to be performed.The AP05 helps avoid wrong machine settings and enhances process safety of flexible production machines.
Profile AP05
Mechanical data
Feature | Technical data | Additional information |
---|---|---|
Shaft | plastic | |
Housing | reinforced plastic | plug thread / PE connection metal |
Color | black, RAL 9005 | |
Clamping ring | stainless steel | |
Speed | ≤500 rpm | |
Cable sheath | PUR | EX15 type of connection |
Cable bending radius | ≥30 mm | permanently laid |
Weight | ~0.07 kg |
Electrical data
Feature | Technical data | Additional information |
---|---|---|
Operating voltage | 24 V DC ±20 % | reverse polarity protected |
Current consumption | ~30 mA | |
Battery service life | ~8 year(s) | |
Parameter storage | 105 cycles | also applies to calibration operations |
Display/display range | 5-digit LCD 7-segment, ~6 mm height | decimal points, 2 rows, special characters (LED backlit red/white) |
Special character | arrow clockwise, arrow conter-clockwise, incremental dimension, battery | |
Status display | 2x two-color LED (red/green) | position status, configurable |
Keys | incremental measurement function, parameterizing, resetting | |
Bus connection | RS485; CANopen | no galvanic isolation |
Type of connection | 2x M8-plug connectors (A-coded) | 4-pole, 1x socket, 1x pin |
grounding via flat connector 6.3 mm |
System data
Feature | Technical data | Additional information |
---|---|---|
Scanning | magnetic | |
Resolution | 720 increments/revolution | displayed value/revolution freely configurable |
Measuring range | ≤932067 revolution(s) | coded |
Ambient conditions
Feature | Technical data | Additional information |
---|---|---|
Ambient temperature | 0 … 60 °C | |
Storage temperature | -20 … 80 °C | |
Relative humidity | condensation inadmissible | |
EMC | EN 61326-1 | Industrial immunity requirements, class B emission limit |
Protection category | IP53 | EN 60529, in the fitted condition, with mating connector mounted |
IP65 | EN 60529, in the fitted condition, with mating connector mounted | |
Shock resistance | ≤500 m/s2, 11 ms | EN 60068-2-27, half-sine, 3 axes (+/-), each 3 pulses |
Vibration resistance | ≤100 m/s2, 10 … 2000 Hz | EN 60068-2-6, 3 axes, each 10 cycles |