Products
E+H, Endress+Hauser Guided Radar Level Transmitter Levelflex M FMP40

E+H, Endress+Hauser Guided Radar Level Transmitter Levelflex M FMP40

Brand: Endress + Hauser
Model No: FMP40
$0.00
Qty: Add to Cart
E+H, Endress+Hauser Guided Radar Level Transmitter Levelflex M FMP40

Continuous Level Transmitter for

- Level Measurement in Bulk Solids and Liquids

- Interface Measurement in Liquids

Your benefits

- Probes are available with threaded process connections

- from ¾" and flanges from DN40 (1½").

- Rope probes, above all for measurement in bulk solids, measuring range up to 35 m.

- Rod probes, above all for liquids.

- Coax probes, for liquids.

- Simple, menu-guided onsite operation with four-line plain text display.

- Onsite envelope curve on the display for easy diagnosis.

- Easy remote operation, diagnosis and measuring point documentation with the free operating program supplied.

- Optional remote display and operation.

- With coax probes the measurement is independent of internals in the tank and of the installation in the nozzle.

- Probe rod and probe rope can be replaced/shortened.

- Approvals: ATEX, FM, CSA, TIIS, NEPSI, IECEx.

Endress+Hauser Guided Radar Level Transmitter Levelflex M FMP40

Level measurement

Continuous level measurement of powdery to granular

bulk solids e.g. plastic granulate and liquids.

- Measurement independent of density or bulk weight, conductivity, dielectric constant, temperature and dust e.g. during pneumatic filling.

- Measurement is also possible in the event of foam or if the surface is very turbulent.

- The HART with 4 to 20 mA analog, PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration.

- Application in safety related systems (overspill protection) with requirements for functional safety up to SIL 2 in accordance with IEC 61508/IEC 61511-1.

- WHG approval.

Interface measurement

Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water for example.

- Measurement independent of density, conductivity and temperature.

- Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration.

- Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration.