The Check-Line TI-CMX accurately measures coating and wall thickness on a wide range of materials. Five selectable measuring modes enable the operator to precisely measure wall thickness, coating thickness and locate corrosion and pitting—without removing the coating.
Oversized graphic LCD is backlit and features an easy to navigate menu allowing quick access to gauge settings and options.
Five user-selected operating modes are included:
Coating On: Measures wall thickness using Pulse-Echo. It separately displays wall & coating thickness.
Coating Off: Measures wall thickness using Pulse-Echo. It displays wall thickness only.
Temperature Compensated: Measures wall thickness using Pulse-Echo and automatically adjusts calibration to compensate for changes in material temperature.
Thru-Coat: Measures wall thickness only using Echo-Echo. (coating is NOT included)
Coating Only Mode (CT): (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.013 to 2.540 mm). Range will vary slightly depending on the coating.
Features
Complete Kit
The TI-CMX is supplied as a complete kit with the gauge, probe, 4 oz. bottle of coupling fluid, 2 AA batteries, NIST-Traceable Calibration Certificate, operating manual, Software, RS-232 output cable, RS-232 to USB adapter, all in a foam-fitted carrying case.
Specifications
Range in Steel: | Pulse-Echo Mode: Pit and Flaw detection measures from 0.025 - 9.999inches (0.63 to 254 millimeters) Echo-Echo Mode: Thru Paint & coatings measures from 0.100 - 4.000 inches (2.54 to 102 mm). Range will vary depending on the thickness |
Range in Coating Only Mode | 0.0005" - 0.1000" / Resolution: 0.0001" (0.013 - 2.540 mm / Resolution: 0.001 mm) |
Max Coating | 0.100" (2.54mm) |
Resolution: | .001 inches (0.01mm) |
Velocity Range: | .0492 to .3936 in./ms 1250 to 9999 meters/sec |
Units: | Inch or mm |
Measurement Modes: | - Pulse-Echo (corrosion mode) - Pulse-Echo Coating (Corrosion w/o coating) - Echo-Echo (thru-paint) - Temp Comp (auto adjust for material temp) - Coating Only (Ultrasonic Coating Gauge) |
Transducer Types: | Dual Element (1 to 10 MHz). |
Output | RS-232 for upload/download of setups |
Memory capacity: | TI-CMX: None TI-CMXDL: over 200,000 measurements |
Power Source: | Three 1.5V alkaline or 1.2V NiCad AA cells |
Battery Life: | Typically operates for 150 hours on alkaline and 100 hours on NiCad |
Auto Power off: | After 5 minutes of non-use |
Display: | 1/8 in. VGA grayscale display 62 x 45.7mm |
Keyboard: | Membrane switch with twelve tactile keys |
Case: | Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed). |
Temp. Limits | Ambient: -20 to 120° F (-30 to 50° C) Material: -0 to 200° F (-20 to 100° C) Special high temperature model TI-CMX-H is available for 300°F/150°C and optional probes are offered for higher surface temperatures |
Weight, net: | 383 grams |
Dimensions: | 63.5 W x 165 H x 31.5 D mm |
Certification: | CE Approved, Factory calibration traceable to national standards |