A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

 

Technical data

Number of Main Contacts NO:

3

Number of Main Contacts NC:

0

Number of Auxiliary Contacts NO:

1

Number of Auxiliary Contacts NC:

0

Rated Operational Voltage:

Auxiliary Circuit 690 V
Main Circuit 690 V

Rated Frequency (f):

Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith):

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 45 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A

Rated Operational Current AC-1 (Ie):

(690 V) 40 °C 45 A
(690 V) 55 °C 40 A
(690 V) 70 °C 32 A

Rated Operational Current AC-3 (Ie):

(415 V) 55 °C 26 A
(440 V) 55 °C 26 A
(500 V) 55 °C 22 A
(690 V) 55 °C 17 A
(380 / 400 V) 55 °C 26 A
(220 / 230 / 240 V) 55 °C 26

Rated Operational Power AC-3 (Pe):

(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW

Rated Operational Power AC-6b (Pe):

(230 / 240 V) 40 °C, 50 / 60 Hz 11.5 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 11.5 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 9 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 19 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 15 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 19 kvar
(440 V) 40 °C, 50 / 60 Hz 20 kvar
(440 V) 55 °C, 50 / 60 Hz 20 kvar
(440 V) 70 °C, 50 / 60 Hz 16.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 23 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 23 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 19 kvar
(690 V) 40 °C, 50 / 60 Hz 32 kvar
(690 V) 55 °C, 50 / 60 Hz 32 kvar
(690 V) 70 °C, 50 / 60 Hz 26 kvar

Rated Breaking Capacity AC-3:

8 x Ie AC-3

Rated Making Capacity AC-3:

10 x Ie AC-3

Rated Operational Current AC-15 (Ie):

(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A

Short-Circuit Protective Devices:

Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 50 A

Rated Short-time Withstand Current Low Voltage (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A
Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A

Maximum Electrical Switching Frequency:

(AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour

Rated Operational Current DC-13 (Ie):

(24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
(125 V) 1.1 / 138 A
(250 V) 0.55 / 138 A

Rated Insulation Voltage (Ui):

acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):

8 kV

Maximum Mechanical Switching Frequency:

300 cycles per hour

Rated Control Circuit Voltage (Uc):

50 Hz 220 ... 230 V
60 Hz 230 ... 240 V

Coil Consumption:

Average Holding Value 50 / 60 Hz 12 V·A
Average Pull-in Value 50 Hz 125 V·A
Average Pull-in Value 60 Hz 120 V·A

Operate Time:

Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms

Mounting on DIN Rail:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied):

2 x M4 screws placed diagonally

Connecting Capacity Main Circuit:

Flexible with Cable End 0.75 ... 4 mm²
Rigid Cable 1.5 ... 6 mm²

Connecting Capacity Auxiliary Circuit:

Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²

Degree of Protection:

acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20

Connecting Terminals (delivered in open position) Main Poles:

M 4 (+,-) pozidriv 2 screws with cable clamp

Terminal Type:

Screw Terminals