ABB - MS132-1.0 Manual Motor Starter 0.63 ... 1.0 A

ABB - MS132-1.0 Manual Motor Starter 0.63 ... 1.0 A

Brand: ABB
Model No: MS132-1.0
$0.00
Qty: Add to Cart

The MS132-1.0 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.00 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.

 

Technical data

Rated Service Short-Circuit Breaking Capacity (Ics):

(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu):

(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA

Rated Instantaneous Short-Circuit Current Setting (Ii):

12.5 A

Setting Range:

0.63 ... 1.0 A

Rated Operational Power AC-3 (Pe):


(400 V) Three Phase 0.25 kW

Rated Operational Power AC-3e (Pe):


(400 V) Three Phase 0.25 kW

Rated Operational Voltage:

Main Circuit 690 V AC
Main Circuit 250 V DC

Rated Operational Current (Ie):

1 A

Rated Operational Current AC-3 (Ie):

1 A

Rated Operational Current AC-3e (Ie):

1 A

Rated Operational Current DC-5 (Ie):

1 A

Rated Frequency (f):

Main Circuit 50 Hz
Main Circuit 60 Hz

Rated Impulse Withstand Voltage (Uimp):


Main Circuit 6 kV

Rated Insulation Voltage (Ui):

690 V

Power Loss:

at Rated Operating Conditions per Pole 0.6 ... 1.6 W

Number of Poles:

3

Conventional Free-air Thermal Current (Ith):

Main Circuit 1 A

Degree of Protection:

Housing IP20
Main Circuit Terminals IP10

Pollution Degree:

3

Electrical Durability:

50000 cycle

Mechanical Durability:

100000 cycle

Terminal Type:

Screw Terminals

Connecting Capacity Main Circuit:

Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²

Tightening Torque:

Main Circuit 0.8 ... 1.2 N·m

Wire Stripping Length:

Main Circuit 9 mm

Recommended Screw Driver:

Pozidriv 2

Mounting Position:

1 ... 6

Mounting on DIN Rail:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Minimum Mounting Distance:

Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm

Actuator Type:

Rotary Handle

Contact Position Indication:

ON / OFF / TRIP

Standards:

IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1

Remarks:

UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx